ALPOLIC™/FR

Easy to process, but flame-retardant: ALPOLIC™/fr

Description

ALPOLICTM/fr is a composite panel consisting of two 0.5mm thick aluminium cover sheets with a flame-retardant mineral polymer core (2.0 to 5.0mm). It meets the requirements of fire class B – s1, d0 and is approved by the building authorities.


The composite panels convince through easy formability, easy processing with standard tools, variety of colours, weather resistance and low weight. The front side is coated with LUMIFLONTM, based on a high-quality fluoropolymer resin (FEVE). This unique coating ensures greater colour brilliance and resistance to ordinary resins. ALPOLICTM is therefore an ideal material for almost unlimited design possibilities for ventilated façades of any application.

 
Dimensions Standard Unit Value
Total Thickness mm 3* / 4 / 6
Cover sheet thickness mm 0,5
Core thickness mm 2 / 3 / 5
Width mm 1,035 / 1,285 / 1,535 / 1,785 / 2,050 (± 2)
Length mm max. 7,300 (± 1,00mm / m)
Technological Value
Weight kg/m2 6 / 7.6 / 10.9
Tensile strength ASTM E8 N/mm2 49 / 29
0.2% proof stress ASTM E8 N/mm2 44 / 26
Elongation ASTM E8 % 5 / 2
Flexural elasticity, E ASTM D393 kN/mm2 39.8 / 29.1
Deflection temperature ISO 75-2 °C 116 / 109
Thermal expansion ASTM D696 x 10-6/°C 24
Surface
Coil-Coating

LUMIFLONTM -based fluoropolymer coating/ reAL Anodised

Aluminium alloy 3105-H14 / 3005-H14 / 5005A
Gloss (measured at 60°) EN 13523-2 % 15-80
Pencil hardness H
Country Test Standard
EU (applicable in Europe, Switzerland and Turkey) EN 13823, EN ISO 11925-2, EN 13501-1
Great Britain BS 476 Part 6 & 7, BS 8414-1, BS 8414-2
Poland PN / B-02867
Czech Republic CSN 73 0862, CSN 73 0863
Hungary MSZ 14800-6:2009
Austria OENORM B 3800-5
Russia GOST 30244-94 method II, SNIP 21-01-97*, TsNIISK Natural Fire Test
USA NFPA 259-93 (British Thermal Unit), ASTM D1781-76 (Climbing Drum Peel Test), ASTM E-84 (Tunnel Test), ASTM E-108 Modified, UBC 26-9 & NFPA 285 (ISMA Test), ASTM E108 (Fire Test for Roof Covering), ASTM E119 (1-hr and 2-hrs Fire Rating), UBC 26-3 (Interior Room Corner Test), Combustion Toxicity Test New York State Uniform FirePrevention and Building Code
Canada CAN / ULC-S 134-92 (Full-scale Exterior Wall Fire Test)
Japan ISO 5660-1 (Heat Release Test for Non-combustible Material)
China GB8625, GB8628, GB8627
Singapore BS 476 Part 6 & 7, Local fire regulation
Malaysia BS 476 Part 6 & 7, ISO 9705:1993, Local fire regulation

Want to know more?